import threading import time from flask import Flask, jsonify, render_template, request from pysolarmanv5 import PySolarmanV5 from writable_registers import WRITABLE, validate_write try: import config except ImportError: raise SystemExit( "config.py not found. Copy config.py.example to config.py and fill in your inverter details." ) app = Flask(__name__) SOCKET_TIMEOUT = getattr(config, "INVERTER_SOCKET_TIMEOUT", 5) # The dashboard polls every CLIENT_POLL_INTERVAL seconds. Cache a reading for slightly # less than that, so one client's poll refreshes the data and any other clients polling # within the window get the cached reply (the logger only tolerates one session at a time). CLIENT_POLL_INTERVAL = 5.0 CACHE_TTL = CLIENT_POLL_INTERVAL - 0.2 _lock = threading.Lock() _cache = {"time": 0.0, "data": None} # BMS packs: 14 registers each starting at 600 (pack 1 = 600-613 ... pack 15 = 796-809) BMS_BASE = 600 BMS_PACK_SIZE = 14 BMS_MAX_PACKS = 15 BMS_RESCAN_INTERVAL = 300.0 # seconds between full scans for connected packs MAX_READ_CHUNK = 100 # registers per Modbus read # Pack numbers (1-based) that reported data at the last scan; None = not scanned yet. _bms_state = {"packs": None, "scanned": 0.0} def to_signed(val): return val if val < 32768 else val - 65536 def swap_bytes(raw): return ((raw & 0xFF) << 8) | (raw >> 8) def read_registers(inverter, start, count): """Read `count` holding registers in chunks the logger handles reliably.""" values = [] while len(values) < count: chunk = min(MAX_READ_CHUNK, count - len(values)) values.extend(inverter.read_holding_registers(register_addr=start + len(values), quantity=chunk)) return values def pack_registers(bms, pack): i = (pack - 1) * BMS_PACK_SIZE return bms[i:i + BMS_PACK_SIZE] def detect_active_packs(bms): """Packs whose module voltage or SOC register is non-zero. Empty packs read as zeros apart from a constant placeholder in the temperature register, so only voltage (offset 0) and SOC (offset 3) are checked. Zero is the same with or without byte swapping. """ return [n for n in range(1, len(bms) // BMS_PACK_SIZE + 1) if pack_registers(bms, n)[0] != 0 or pack_registers(bms, n)[3] != 0] def parse_bms_pack(pack, regs): """Decode one pack. SOC is in 0.1% (<= 1000). Some packs (seen on pack 2) are reported byte-swapped by the firmware, so if the raw SOC is out of range but becomes valid after swapping, swap every register of the pack back.""" soc_raw = regs[3] if soc_raw > 1000 and swap_bytes(soc_raw) <= 1000: regs = [swap_bytes(r) for r in regs] return { "pack": pack, "voltage": round(regs[0] * 0.01, 2), # 0.01V "current": round(to_signed(regs[1]) * 0.1, 1), # 0.1A, negative = discharge "temp": round((regs[2] - 1000) * 0.1, 1), # offset +1000, 0.1C "soc": round(regs[3] * 0.1, 1), # 0.1% "charge_voltage": round(regs[6] * 0.01, 2), # 0.01V "charge_current_limit": round(regs[7] * 0.1, 1), # 0.1A, BMS-requested limit } def connect(): return PySolarmanV5( config.INVERTER_IP, config.INVERTER_SERIAL, port=config.INVERTER_PORT, mb_slave_id=config.INVERTER_SLAVE_ID, socket_timeout=SOCKET_TIMEOUT, verbose=False ) def get_inverter_data(): """ Connects to the inverter and reads voltage registers. Returns a dictionary with the data. """ inverter = None try: inverter = connect() # Reading blocks: # Block 1: 150 - 216 (67 registers) - Voltages, Currents, Battery, PV, Control # Block 2: 600 - 809 (up to 15 packs x 14 registers) - BMS Data # Block 3: 245 (1 register) - Max Grid Output # Block 4: 292 - 293 (2 registers) - Peak Shaving # Block 5: 312 - 325 (14 registers) - Lithium battery / BMS limits block1 = inverter.read_holding_registers(register_addr=150, quantity=67) # BMS: scan all possible packs on first use and every BMS_RESCAN_INTERVAL; # otherwise only read up to the last pack that was found. now = time.monotonic() scan = (_bms_state["packs"] is None or now - _bms_state["scanned"] >= BMS_RESCAN_INTERVAL) if scan: bms_count = BMS_MAX_PACKS else: bms_count = max(_bms_state["packs"], default=0) bms = read_registers(inverter, BMS_BASE, bms_count * BMS_PACK_SIZE) if bms_count else [] block3 = inverter.read_holding_registers(register_addr=245, quantity=1) block4 = inverter.read_holding_registers(register_addr=292, quantity=2) block6 = inverter.read_holding_registers(register_addr=230, quantity=1) block5 = inverter.read_holding_registers(register_addr=312, quantity=14) data = {} # Block 1 Parsing (150-216) data["input_voltage"] = round(block1[0] * 0.1, 1) # 150 data["output_voltage"] = round(block1[4] * 0.1, 1) # 154 data["load_voltage"] = round(block1[7] * 0.1, 1) # 157 data["grid_current"] = round(to_signed(block1[10]) * 0.01, 2) # 160 data["grid_clamp_current"] = round(to_signed(block1[12]) * 0.01, 2) # 162 data["output_current"] = round(to_signed(block1[14]) * 0.01, 2) # 164 data["load_current"] = round(to_signed(block1[29]) * 0.01, 2) # 179 data["batt_temp"] = round((block1[32] - 1000) * 0.1, 1) # 182 (offset +1000, 0.1C) data["batt_voltage"] = round(block1[33] * 0.01, 2) # 183 data["batt_soc"] = block1[34] # 184 data["batt_charge_status"] = block1[35] # 185 data["pv1_power"] = block1[36] # 186 data["pv2_power"] = block1[37] # 187 data["batt_power"] = to_signed(block1[40]) # 190 data["batt_current"] = round(to_signed(block1[41]) * 0.01, 2) # 191 data["grid_relay_status"] = block1[44] # 194 data["gen_relay_status"] = block1[45] # 195 data["max_charge_current"] = block1[60] # 210 data["max_discharge_current"] = block1[61] # 211 data["batt_charge_efficiency"] = round(block1[66] * 0.1, 1) # 216 (0.1%) # Block 2 Parsing (BMS packs) if scan: _bms_state["packs"] = detect_active_packs(bms) _bms_state["scanned"] = now data["bms_packs"] = [parse_bms_pack(n, pack_registers(bms, n)) for n in _bms_state["packs"] if n * BMS_PACK_SIZE <= len(bms)] # Block 3 Parsing (245) data["max_grid_output_power"] = block3[0] # 245 # Register 230 (writable) data["grid_charge_current"] = block6[0] # 230 (1A) # Block 4 Parsing (292-293) data["gen_peak_shaving_power"] = block4[0] # 292 data["grid_peak_shaving_power"] = block4[1] # 293 # Block 5 Parsing (312-325, index = register - 312) data["charge_voltage"] = round(block5[0] * 0.01, 2) # 312 data["discharge_voltage"] = round(block5[1] * 0.01, 2) # 313 data["charge_current_limit"] = block5[2] # 314 data["discharge_current_limit"] = block5[3] # 315 data["real_time_capacity"] = block5[4] # 316 data["real_time_voltage"] = round(block5[5] * 0.01, 2) # 317 data["real_time_current"] = to_signed(block5[6]) # 318 data["real_time_temp"] = round((block5[7] - 1000) * 0.1, 1) # 319 (offset +1000) data["max_charge_current_limit"] = block5[8] # 320 data["max_discharge_current_limit"] = block5[9] # 321 # 322-324 skipped (alarm / fault / flags) data["lithium_battery_type"] = block5[13] # 325 data["status"] = "success" return data except Exception as e: return { "status": "error", "message": str(e) } finally: if inverter is not None: try: inverter.disconnect() except Exception: pass def get_cached_data(): """Serialize inverter access and reuse a recent successful reading. Freshness is measured from when the server received the request, not from when the inverter answered, so slow inverter reads don't stretch the cache window. """ arrived = time.monotonic() with _lock: if _cache["data"] is not None and arrived - _cache["time"] < CACHE_TTL: return _cache["data"] data = get_inverter_data() if data.get("status") == "success": _cache["data"] = data _cache["time"] = arrived return data def write_inverter_registers(writes): """Write already-validated {register: value} pairs, reading each back to verify. Returns (applied, error): `applied` maps register -> value confirmed by read-back, `error` is a message for the first failure (None on success). """ applied = {} inverter = None try: inverter = connect() for reg, value in writes.items(): inverter.write_multiple_holding_registers(reg, [value]) readback = inverter.read_holding_registers(register_addr=reg, quantity=1) if not readback or readback[0] != value: got = readback[0] if readback else None return applied, f"Register {reg}: wrote {value} but read back {got}" applied[reg] = readback[0] return applied, None except Exception as e: return applied, f"{type(e).__name__}: {e}" finally: if inverter is not None: try: inverter.disconnect() except Exception: pass @app.route('/') def index(): return render_template('index.html', writable=WRITABLE, poll_interval_ms=int(CLIENT_POLL_INTERVAL * 1000)) @app.route('/api/data') def api_data(): data = get_cached_data() status = 200 if data.get("status") == "success" else 502 return jsonify(data), status @app.route('/api/registers', methods=['POST']) def api_registers(): """Write whitelisted registers. Body: {"writes": {"230": 43, "293": 4500}}. All values are validated before anything is written. Requiring a JSON body means a cross-site form post cannot trigger this (a cross-origin fetch needs a CORS preflight, which this app does not grant). """ body = request.get_json(silent=True) raw = body.get("writes") if isinstance(body, dict) else None if not isinstance(raw, dict) or not raw: return jsonify({"status": "error", "message": 'Body must be {"writes": {"": }}'}), 400 writes = {} for key, value in raw.items(): if not (isinstance(key, str) and key.isascii() and key.isdecimal()): return jsonify({"status": "error", "message": f"Invalid register {key!r}"}), 400 reg = int(key) error = validate_write(reg, value) if error: return jsonify({"status": "error", "message": error}), 400 writes[reg] = value with _lock: applied, error = write_inverter_registers(writes) _cache["data"] = None # force a fresh read after any write attempt if error: return jsonify({"status": "error", "message": error, "applied": applied}), 502 return jsonify({"status": "success", "applied": applied}) if __name__ == '__main__': app.run(debug=False, host='0.0.0.0')