Files
deyeDashboard/app.py
T
Vlad DolomanandClaude Sonnet 5.5 4d1ff0c7ea Fix dashboard bugs, verify register map against manual, harden scripts
- index.html: remove duplicated sections/IDs, restore card CSS, add fetch
  timeout and error handling, label relay and lithium type values
- app.py: close inverter connection in finally, socket timeout, lock plus
  2s cache, debug off, friendly missing-config error, HTTP 502 on failure
- app.py: fix register scaling per Deye Modbus V118 (battery temp +1000
  offset, charge efficiency 0.1%, block 5 off-by-one for 312-325)
- read_registers.py: drop hard-coded IP/serial (env or config.py), use
  argparse type validators, unify INVERTER_SLAVE_ID, document limits
- extract_pdf.py: main guard, argparse, output next to script, pypdf in
  docs/requirements.txt; pin requirements

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
2026-11-06 19:14:33 +02:00

155 lines
6.3 KiB
Python

import threading
import time
from flask import Flask, jsonify, render_template
from pysolarmanv5 import PySolarmanV5
try:
import config
except ImportError:
raise SystemExit(
"config.py not found. Copy config.py.example to config.py and fill in your inverter details."
)
app = Flask(__name__)
SOCKET_TIMEOUT = getattr(config, "INVERTER_SOCKET_TIMEOUT", 5)
CACHE_TTL = 2.0 # seconds; the logger only tolerates one session at a time
_lock = threading.Lock()
_cache = {"time": 0.0, "data": None}
def to_signed(val):
return val if val < 32768 else val - 65536
def get_inverter_data():
"""
Connects to the inverter and reads voltage registers.
Returns a dictionary with the data.
"""
inverter = None
try:
inverter = PySolarmanV5(
config.INVERTER_IP,
config.INVERTER_SERIAL,
port=config.INVERTER_PORT,
mb_slave_id=config.INVERTER_SLAVE_ID,
socket_timeout=SOCKET_TIMEOUT,
verbose=False
)
# Reading blocks:
# Block 1: 150 - 216 (67 registers) - Voltages, Currents, Battery, PV, Control
# Block 2: 600 - 627 (28 registers) - BMS Data
# Block 3: 245 (1 register) - Max Grid Output
# Block 4: 292 - 293 (2 registers) - Peak Shaving
# Block 5: 312 - 325 (14 registers) - Lithium battery / BMS limits
block1 = inverter.read_holding_registers(register_addr=150, quantity=67)
block2 = inverter.read_holding_registers(register_addr=600, quantity=28)
block3 = inverter.read_holding_registers(register_addr=245, quantity=1)
block4 = inverter.read_holding_registers(register_addr=292, quantity=2)
block5 = inverter.read_holding_registers(register_addr=312, quantity=14)
data = {}
# Block 1 Parsing (150-216)
data["input_voltage"] = round(block1[0] * 0.1, 1) # 150
data["output_voltage"] = round(block1[4] * 0.1, 1) # 154
data["load_voltage"] = round(block1[7] * 0.1, 1) # 157
data["grid_current"] = round(to_signed(block1[10]) * 0.01, 2) # 160
data["grid_clamp_current"] = round(to_signed(block1[12]) * 0.01, 2) # 162
data["output_current"] = round(to_signed(block1[14]) * 0.01, 2) # 164
data["load_current"] = round(to_signed(block1[29]) * 0.01, 2) # 179
data["batt_temp"] = round((block1[32] - 1000) * 0.1, 1) # 182 (offset +1000, 0.1C)
data["batt_voltage"] = round(block1[33] * 0.01, 2) # 183
data["batt_soc"] = block1[34] # 184
data["batt_charge_status"] = block1[35] # 185
data["pv1_power"] = block1[36] # 186
data["pv2_power"] = block1[37] # 187
data["batt_power"] = to_signed(block1[40]) # 190
data["batt_current"] = round(to_signed(block1[41]) * 0.01, 2) # 191
data["grid_relay_status"] = block1[44] # 194
data["gen_relay_status"] = block1[45] # 195
data["max_charge_current"] = block1[60] # 210
data["max_discharge_current"] = block1[61] # 211
data["batt_charge_efficiency"] = round(block1[66] * 0.1, 1) # 216 (0.1%)
# Block 2 Parsing (BMS 600-627)
data["bms1_soc"] = block2[3] # 603
data["bms1_charge_voltage"] = round(block2[6] * 0.01, 2) # 606
data["bms1_charge_current"] = round(block2[7] * 0.1, 1) # 607
data["bms2_soc"] = block2[17] # 617
data["bms2_charge_voltage"] = round(block2[20] * 0.01, 2) # 620
data["bms2_charge_current"] = round(block2[21] * 0.1, 1) # 621
# Block 3 Parsing (245)
data["max_grid_output_power"] = block3[0] # 245
# Block 4 Parsing (292-293)
data["gen_peak_shaving_power"] = block4[0] # 292
data["grid_peak_shaving_power"] = block4[1] # 293
# Block 5 Parsing (312-325, index = register - 312)
data["charge_voltage"] = round(block5[0] * 0.01, 2) # 312
data["discharge_voltage"] = round(block5[1] * 0.01, 2) # 313
data["charge_current_limit"] = block5[2] # 314
data["discharge_current_limit"] = block5[3] # 315
data["real_time_capacity"] = block5[4] # 316
data["real_time_voltage"] = round(block5[5] * 0.01, 2) # 317
data["real_time_current"] = to_signed(block5[6]) # 318
data["real_time_temp"] = round((block5[7] - 1000) * 0.1, 1) # 319 (offset +1000)
data["max_charge_current_limit"] = block5[8] # 320
data["max_discharge_current_limit"] = block5[9] # 321
# 322-324 skipped (alarm / fault / flags)
data["lithium_battery_type"] = block5[13] # 325
data["status"] = "success"
return data
except Exception as e:
return {
"status": "error",
"message": str(e)
}
finally:
if inverter is not None:
try:
inverter.disconnect()
except Exception:
pass
def get_cached_data():
"""Serialize inverter access and reuse a recent successful reading."""
with _lock:
now = time.monotonic()
if _cache["data"] is not None and now - _cache["time"] < CACHE_TTL:
return _cache["data"]
data = get_inverter_data()
if data.get("status") == "success":
_cache["data"] = data
_cache["time"] = time.monotonic()
return data
@app.route('/')
def index():
return render_template('index.html')
@app.route('/api/data')
def api_data():
data = get_cached_data()
status = 200 if data.get("status") == "success" else 502
return jsonify(data), status
if __name__ == '__main__':
app.run(debug=False, host='0.0.0.0')