3 Commits

Author SHA1 Message Date
cods4
d4528bd4e8 Update README.md 2024-09-22 16:51:52 +12:00
cods4
051cd8133a Add files via upload 2024-09-22 16:19:42 +12:00
cods4
606fe1a248 Update README.md 2024-09-22 16:14:21 +12:00
4 changed files with 13 additions and 4 deletions

View File

@@ -0,0 +1 @@
f70fa648eb98a9997756794a7937d1217816a99ab5a6f303b3ef2f65baf925c8 MCU1-SG-Ver0000-C372-CK.bin

Binary file not shown.

View File

@@ -0,0 +1 @@
d28f2234607300134ffc141fd116e5e7e6c8a2596fe0dd1195f42889215ffa58 SG_5K_MCU2_V3387-NR.bin

View File

@@ -53,6 +53,7 @@ http://47.254.36.66/0_D0002_18/MW3_15_0501_1.23.bin
# Deye Hybrid Inverters HMI Firmware (MCU1)
http://47.254.36.66/0_5407_1/MCU1-SG-Ver0000-C362-CK.bin
http://47.254.36.66/0_5407_1/MCU1-SG-Ver0000-C36E-CK.bin
http://47.254.36.66/0_5407_1/MCU1-SG-Ver0000-C372-CK.bin
# Deye Hybrid Inverters Main Firmware (MCU2)
http://47.254.36.66/0_5407_1/SG_5K_MCU2_V3387-NR.bin (SUN-5K-SG04LP1-AU)
@@ -113,10 +114,16 @@ HMI: MCU1-SG-Ver0000-C366-CK.bin
Based on information in this forum thread: https://powerforum.co.za/topic/12655-deye-inverter-latest-firmware/
It is recomended to update the HMI first, followed by the Main firmware. Generally the HMI firmware update doesn't result in the inverter shutting down the outputs, but the Main firmware normally does.
The update process is fairly straightforward. Deye's instructions can be found here: hybrid-inverter-info/LOCAL UPDATE INSTRUCTIONS.pdf
The default login and password for the solarman dongle is admin/admin.
I found that one of my inverters needed to be power cycled before it would accept the new firmware.
And sometime the firmware upload would start again after the initial upload unless I unplugged the solarman dongle.
Update Procedure :
1) Go to the IP address of the WiFi module of the inverter (stick logger), login : admin\admin
2) On the left, click the Upgrade inverter item (the inverter itself, not the Stick Logger firmware)
3) Select HMI file, i.e. MCU1-SG-Ver0000-C36E-CK.bin (MCU1 = HMI) as the first file, click upgrade. (time +/- 15 minutes)
4) After rebooting, repeat the procedure, but now select the MAIN firmware file, i.e. SG_6K_MCU2_V4386-NR.bin (MCU2 = MAIN). (time +/- 15 minutes)
FYI : the WiFi Stick Logger can also be updated by the Deye service (yet another firmware).
If you have difficulty, you may need to powercycle the inverter before beginning the process.
## Summary of HMI firmware changes (see photos here hybrid-inverter-info/HMI-photos)